I have a Uni-Sonic Instruments System, Model EC 200-1 and T200-1-1-EP-N Serial No. 1841 (Date in service June 15, 1977). Broadcast frequency is 218 kHz. The vendor manual I have for this hardware is dated 1973.This application measures level of product and the voltage is inverted with zero reference point 14 ft from the mounting flange. The output signal is 0-5 VDC over 0-14 ft. My Operators report that the level alarms for this unit are actuating early, causing level of product in the vessel to be less than expected. I\'ve found very little other information onsite about operation of this equipment. Are you familar with this admittedly antiquated hardware, and if so, is it parts supported? Finally, Please advise
If you need your Inventron unit tested or repaired,
give us a call at 1-336-969-0110.
We offer fair estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.
Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.
Show More