I have the Soren Lynso Universal Monitoring System fitted onboard. The vessel is built by Harland & Wolff in 1982. i have recently done lot of tuning up of the ship board computer system. System is built around and 8080 cpu and with 8k RAMs. the tuning up procedure of A/D converter mentioned in the manual states to zeroise the analog display before adjusting the A/D converter but the procedure is not available with me. The system comprises of AC 1 analog cards with NO 2/ DBA cards for contact inputs.All the parameters read by the systme tend to read higher than actual values. Could it be possible to get the procedure for adjustin the A/D converter including the analog display. as it shows a value of + 565 with no input connected to it. It would be very much appreciated if you can help me in this regard
—> Purchase or Repair:
If you need your Soren T. Lyngso unit tested or repaired,
give us a call at 1-336-969-0110.
Estimates are free with an approved repair. Declined or unrepairable units are subject to a $75 evaluation, handling, and standard return-shipping fee. Extended warranties may be available.
Shipping/Receiving:
Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
Phone: 1-336-969-0110
Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
🚑 Rush repair shipments only — no walk-ins.
Industrial Electronic Repair
124 Five Forks Dr PMB #208
King, NC 27021
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.
—> Purchase or Repair: