Westronics Service & Repair Forum

Hello, I'm following up on the Westronics CS1778-1 11701 Moisture Recorder as requested. Can this be repaired or replaced? Just looking to check this off my to-do list.

—> Purchase or Repair: Ticket Image

— Posted by steve kreie on 2012-07-20

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Westronics"

If you need your Westronics unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 134 Comments

#Westronics by Joe Sayre on 2007-05-29 22:23
We received new printed circuits P/N CB100161-02 for a Westronics DDR10 Recorder. The new circuits are stamped with a Rev. H. the previous Circuits were stamped with Rev.D.I need help what is the difference in design change between Rev. D and Rev.H. Are there drawings available for both board revisi…Purchase or Repair: Ticket Image...
Show More
#Westronics by william l jennings on 2013-10-02 18:55
The Westronics Series 2600 2600-111-000-000-11 chart recorder is not functioning properly. The display is showing Error Code E2 consistently. Please advise on the next steps to troubleshoot and resolve this issue. Thank you.

—> Purchase or Repair:
#Westronics by Russ Vatalaro on 2013-04-27 00:22
Could you please confirm if the Westronics Series 2600 2600-111-000-000-11 chart recorder is still supported, and if replacement parts are available for this unit? Thank you.

—> Purchase or Repair:
#Westronics by justilio on 2013-01-13 23:37
The Westronics SDI 300 is displaying error code "E-5" along with a continuous beeping alarm. Equipment is currently down, unable to display any data. Please advise on next steps for troubleshooting and repair. Thank you.

—> Purchase or Repair:
#Westronics by eyuphan on 2012-11-18 00:08
Please provide me with more details about your Westronics CS1778-1 11701 Moisture Recorder. Is this product still supported, and are replacement parts available for it? Thank you.

—> Purchase or Repair:
#Westronics by escelott on 2012-08-04 15:24
Westronics CS1778-1 11701 moisture recorder display showing "Error Code E4".

—> Purchase or Repair:
#Westronics by Gayland Testerman on 2005-12-30 02:51
The Westronics DDR10 PA100056-01 is causing frequent line stoppages due to a malfunctioning heating element. Immediate repair is needed to avoid production delays.

—> Purchase or Repair:
#Westronics by Richard Zelm on 2015-06-26 17:04
Can you please tell me what the measurement voltage is that the SBAG Ground Monitor uses to monitor the insulation? Is it 24 VDC? I can\'t find anything in their specs that tells you what the output voltage is that monitors the insulation. Thanks!

—> Purchase or Repair:
#Westronics by Stiner on 2013-07-14 03:57
I noticed that our Westronics SDI 300 SDI-0-130-010-00 Smart Digital Indicator is not functioning properly. It seems like something has stopped working, and I'm unsure what the exact issue might be. Can someone take a look at it to diagnose the problem?

—> Purchase or Repair:
#Westronics by RORY FISHER on 2013-07-03 14:39
the Westronics Series 2600 2600-111-000-000-11 chart recorder unit went down mid-shift. Need someone to follow up during the day. Thanks!

—> Purchase or Repair:
#Westronics by Curt Nunier on 2013-08-16 12:32
The Westronics SDI 300 SDI-0-130-010-00 unit at the shop is not working.

—> Purchase or Repair:
#Westronics by Joe Harvat on 2006-01-31 00:00
Looking for repair service for a malfunctioning Westronics CB100351-01 MUX 64 Point unit. experiencing intermittent signal loss and data transmission issues. Need assistance urgently.

—> Purchase or Repair:
#Westronics by yasser on 2013-01-05 13:00
Hello, I'm reaching out on behalf of a client who has a Westronics Series 2600 chart recorder with the part number 2600-111-000-000-11 that requires servicing. Could you please provide details on repair options and estimated costs? Thank you.

—> Purchase or Repair:
#Westronics by D Scott Manatt on 2013-05-17 10:54
The Westronics SDI 300 SDI-0-130-010-00 is displaying error code E302. The display screen is flickering on and off intermittently. Need immediate assistance to troubleshoot and resolve the issue.

—> Purchase or Repair:
#Westronics by Andrew Podaca on 2013-12-05 16:48
Looking for repair on Westronics SDI 300 SDI-0-130-010-00. Digital display not functioning properly, in need of technician for repair. Thank you.

—> Purchase or Repair:
#Westronics by Sharon Casey on 2006-09-13 23:11
I am a business customer with a Westronics SM100 Servo Drive unit that is not functioning properly. The unit is failing to respond to commands, resulting in erratic movements and inconsistent performance. Based on the initial assessment, the repair cost is estimated to exceed $1000 due to the comple…Purchase or Repair: Ticket Image...
Show More
#Westronics by HJ on 2005-12-30 23:51
The Westronics DDR10 PA100056-01 is experiencing repeated PCB failures, resulting in frequent downtime on the production line. Urgent repair service needed to avoid further delays and loss of output.

—> Purchase or Repair:
#Westronics by Andzelika on 2013-06-21 15:58
Hey, the Westronics Series 2600 2600-111-000-000-11 is not functioning properly. Maintenance team needs to take a look at it.

—> Purchase or Repair:
#Westronics by steve kreie on 2012-07-20 03:04
Hello, I'm following up on the Westronics CS1778-1 11701 Moisture Recorder as requested. Can this be repaired or replaced? Just looking to check this off my to-do list.

—> Purchase or Repair:
#Westronics by Asheen Inderpal on 2011-02-16 11:42
Good day,I have an enquiry to quote for the following items:1)GROUNDING RESISTANCE MONITOR(INSULATON),MANUFACTURER:WESTRONICS/SEOBU ELECTRONICS- 102,AC110V60HZ,5UA. QNTY:12)GROUNDING RESISTANCE MONITOR :CO-SBG-241D,DC19-30V.0.001-0.2MOM ALARM.QNTY-1,MADED,WESTRONICS./SEOBU ELECTRONICS3)GROUP ANNUNCI…Purchase or Repair: Ticket Image...
Show More
#Westronics by DANIEL ZIJLMANS on 2025-05-28 08:29
Machine displaying "Error Code 101."

—> Purchase or Repair:
#Westronics by Jim Lee on 2011-09-19 14:52
We have a Westronics 3200 Temperature scanner, S/N 1088, we\'d like to know if it could be repaired? It may need chart drive motor, P/N MA100018-01,circuit board, P/N CB100341-04, printhead cartridge motor, P/N MA100015, and power supply, ZB100798-01. The MUX would be sent with unit, not sure if it\…Purchase or Repair: Ticket Image...
Show More
#Westronics by Reccardi on 2013-07-17 20:44
Experiencing issues with Westronics SDI 300 SDI-0-130-010-00 Smart Digital Indicator - unit not displaying any output readings. Please advise on troubleshooting steps or possible solutions. Thank you.

—> Purchase or Repair:
#Westronics by larry c. naffziger on 2013-07-09 05:32
I have a Westronics SDI 300 SDI-0-130-010-00 Smart Digital Indicator that is no longer displaying any information. Looking for repairs ASAP.

—> Purchase or Repair:
#Westronics by jonas hofer on 2019-04-24 15:01
We've got a Westronics CB100356-02C CHART DRIVE BD down. Unclear on the malfunction details, will investigate further ASAP.

—> Purchase or Repair:
#Westronics by Knud Oellgaard on 2012-02-18 14:17
The Westronics CS1778-1 11701 moisture recorder is not powering on.

—> Purchase or Repair:
#Westronics by k johnpaul on 2011-12-02 15:35
One of our sensor monitor out put is -5 MA against the full scale out put of 1 MA. The sensor is in alarm condition. The insulation indicator needle is in the -ve direction, kindly advise.

—> Purchase or Repair:
#Westronics by Qasim on 2013-08-07 00:32
Westronics 345#14588 chart recorder is not printing anything on the chart paper.

—> Purchase or Repair:
#Westronics by Helgert on 2014-03-04 00:00
Machine Issue Westronics CB100356-02 board not powering on, causing production downtime.

—> Purchase or Repair:
#Westronics by Ene on 2005-12-28 00:12
We are experiencing consistent short-circuits on the Westronics DDR10 PA100056-01, halting our production line. Urgent attention and repair service are needed to resolve this issue

—> Purchase or Repair:
#Westronics by Olejnik Leszek on 2012-01-01 04:39
Manual and documentation for PCB

—> Purchase or Repair:
#Westronics by ric houle on 2013-06-21 01:00
Hello, I'm contacting you on behalf of a client who has a Westronics Series 2600 2600-111-000-000-11 chart recorder that requires repair. Could you please provide more information on the services you offer for this specific model? Thank you.

—> Purchase or Repair:
#Westronics by sunil sapkal on 2006-05-29 17:42
The power supply unit on the Westronics DDR10 PA100056-01 is malfunctioning, causing a halt in production. Please prioritize the repair service to get the line back up and running swiftly.

—> Purchase or Repair:
#Westronics by Monzur Raiha on 2012-12-24 11:24
Hello, I am interested in purchasing a Westronics CS1778-1 11701 Moisture Recorder. I would like to inquire about the pricing and availability of this unit. I am looking to source one quickly. Thank you.

—> Purchase or Repair:
#Westronics by Carlos Melo on 2008-10-26 11:08
The power supply on Westronics 3000 PA100056-03 just failed. Need immediate attention to get it back up and running.

—> Purchase or Repair:
#Westronics by Shefts on 2013-02-07 00:44
The Westronics 345#14588 chart recorder is not working.

—> Purchase or Repair:
#Westronics by Grant-Henderson on 2012-02-25 15:51
The Westronics CS1778-1 11701 moisture recorder unit in the warehouse is exhibiting abnormal behavior.

—> Purchase or Repair:
#Westronics by Kreming on 2007-12-19 08:16
We apologize for the lack of response regarding your Westronics 3000 PA 1000 56-03 power supply issue. Please provide an update on the progress on resolving this matter as soon as possible. Your

—> Purchase or Repair:
#Westronics by kulwnt on 2013-05-12 15:20
My Westronics SDI 300 SDI-0-130-010-00 Smart Digital Indicator is malfunctioning and needs repair. Seeking help from a professional technician experienced with industrial units. Thank you.

—> Purchase or Repair:
#Westronics by Dunham on 2012-04-14 15:33
The Westronics CS1778-1 11701 Moisture Recorder is malfunctioning, causing a halt in our production line. Urgent repair and resolution are needed to minimize operational downtime.

—> Purchase or Repair:
#Westronics by Blaire Farrington on 2013-08-17 16:01
Our Westronics Series 2600 2600-111-000-000-11 Chart Recorder is still down. Can someone please get back to me on this issue

—> Purchase or Repair:
#Westronics by Cottrell on 2005-12-27 18:12
The Westronics DDR10 PA100056-01 is causing frequent production line interruptions due to erratic temperature control. Immediate service is required to avoid significant production delays.

—> Purchase or Repair:
#Westronics by Timothybum on 2013-05-16 22:54
Hi there! Could you please provide repair information for a Westronics 345#14588 chart recorder? We are in urgent need of a replacement part. Thank you!

—> Purchase or Repair:
#Westronics by andrade on 2005-02-23 01:00
It seems like the Westronics DDR-10 PA100056-01 is experiencing some issues. I'm not entirely sure what the model does, but it seems like something has stopped working. We'll need to look into this further to figure out the problem.

—> Purchase or Repair:
#Westronics by MAHESH KHANDWE on 2008-09-26 05:16
The Westronics 3000 PA100056-03 power supply unit is not functioning as expected. The unit is displaying unusual behavior and is acting erratically. Please advise on how to proceed. Thank you.

—> Purchase or Repair:
#Westronics by mariolis georgios on 2010-02-11 13:14
Good day Sir/Mr(s)I would like to find the manual concerning the terminals of the model above but unfortunatelly i can\'t.I would appreciate if you could mail me this document.Thank you in advanceMariolis Georgios

—> Purchase or Repair:
#Westronics by Nailor on 2013-08-12 09:32
Hello, I am reaching out on behalf of a client who needs assistance with a Westronics Series 2600 (2600-111-000-000-11) chart recorder. They are experiencing some issues and would like to inquire about repair services. Can you please provide more information on troubleshooting steps and potential re…Purchase or Repair: Ticket Image...
Show More
#Westronics by ROB DYCK on 2012-09-21 15:47
The Westronics CS1778-1 11701 Moisture Recorder unit is not working.

—> Purchase or Repair:
#Westronics by buscemi on 2012-08-30 16:31
The Westronics CS1778-1 11701 Moisture Recorder is displaying error code E02 and not responding to input commands. Please advise on troubleshooting steps or schedule a technician visit as soon as possible.

—> Purchase or Repair:
#Westronics by Henning Hamann on 2008-02-26 07:13
Hallo,I need the price and the availability for a Grounding resistance montitor, Supply Voltage AC 110V 60Hz, for 440V bus,Serieal No.: 9C09106, Type SBAG-102 Main switch borad# M4-8235\'41Built in 1999, Manufacturer \"Westronics\"\"Seobu el\" KoreaI Need the price for a new one.I Hope you can help …Purchase or Repair: Ticket Image...
Show More

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.