Looking for repair service for Atlas Copco Electronikon 1900-0701-04 Display Unit. Screen not displaying any information, need quick resolution for production unit.

β€”> Purchase or Repair: Ticket Image

β€” Posted by cheripady on 2011-03-10

ReplyπŸ—¨οΈAsk a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by Ntsako Mabunda on 2016-11-16 10:24
Hi,I need a detailed wiring diagram for part nr. : 1900 0710 32. It is a control card / display unit for my Atlas Copco compressor.

β€”> Purchase or Repair:
#Atlas Copco by VIJAY.M on 2011-09-30 11:30
WE ARE VERY HAPPY WITH PRECISE PERFORMANCE WITH GA18+ MODEL

β€”> Purchase or Repair:
electric wiring tampered with

β€”> Purchase or Repair:
#Atlas Copco by dulan on 2011-03-16 17:27
it is world no 1

β€”> Purchase or Repair:
#Atlas Copco by Edwin on 2009-08-23 13:59
Tengo un GA 30 fuera de servicio y para habilitarlo necesito el diagrama electrico o las conexiones del electronikon 1900 0700 08

β€”> Purchase or Repair:
#Atlas Copco by aamir on 2013-07-05 15:09
we are using GA75 Atlas Copco the ELEKTRONIKON MODULE showing fault \'system failure\' so please give us some solution to rectify above problem thanks and regards

β€”> Purchase or Repair:
#Atlas Copco by restKartDoore on 2013-08-17 13:32
I recommend reaching out to Atlas Copco directly to inquire about the support and availability of replacement parts for the Elektronikon 1900070008 control panel for your screw compressor. Kindly ask if this older unit is still supported and if parts are available for repair or replacement. β€”> …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by SONATRACH ALGERIES on 2010-10-28 08:32
rtef w

β€”> Purchase or Repair:
#Atlas Copco by PHAM HAI on 2011-09-01 04:30
Dear Sir, I am from VN, I have one machine Ga22 ( year 2001)now, controller alarm: system failure 11 & 104. machine can not run.I turn off the power and turn on but machine can not run!Pls, tell me, what must I do?Thanks & best regards,

β€”> Purchase or Repair:
#Atlas Copco by Eta Leonard on 2013-12-10 12:55
GA 37 part list manual is of importance to enable my company get genuine parts

β€”> Purchase or Repair:
#Atlas Copco by aobakwe tsheole on 2009-04-18 21:48
please send me troubleshooting manual.

β€”> Purchase or Repair:
#Atlas Copco by Yeison JF on 2008-02-05 00:18
I'm currently facing an issue with the Atlas Copco 1900 0701 02 Elektronikon. It seems like something has stopped working, but I'm not entirely sure what it does. Can you help me troubleshoot or provide more information on this model?

β€”> Purchase or Repair:
#Atlas Copco by Jack Mc Sweeney on 2015-08-02 21:20
I'm experiencing some issues with the Atlas Copco Elektronikon II 1900071012 compressor controller. It seems like something has stopped working properly. I'm not entirely sure what the model does, but I wanted to reach out for assistance with troubleshooting.

β€”> Purchase or Repair:
#Atlas Copco by yahya asy on 2009-02-02 14:05
please i need service manual for Elektronikon II

β€”> Purchase or Repair:
#Atlas Copco by syed tariq hussain on 2013-07-09 17:32
Hi there, I'm interested in the Atlas Copco GA45 1900.0590.74 controller. I'd like to inquire about the pricing and availability of this unit as I am looking to source one quickly. Thank you!

β€”> Purchase or Repair:
#Atlas Copco by cal on 2012-08-05 10:24
My Atlas Copco 1900-0700-08 controller is displaying an error code and not responding. Looking for a technician who can diagnose and repair the issue

β€”> Purchase or Repair:
#Atlas Copco by DEBASISH GOUDA on 2009-09-15 10:00
Electronikon controller is a very good controller.

β€”> Purchase or Repair:
#Atlas Copco by adam bruce on 2006-02-16 20:42
Provided are to Atlas Copco part numbers I will need quotes or rates to have these items repair. Please provide this aswll as turn around time at your earliest convenience.1900 0701 24 & 1900 0701 06ThanksAdam

β€”> Purchase or Repair:
#Atlas Copco by ARCHAMBAUD on 2008-02-29 15:04
Hi, I\'m a student in training period. I\'m looking for an electronikon 2 datasheet because I want supervize the compressor. I want to know if it\'s possible to pilot the machine by an electromechanical contactor. Is it possible to pilot electronikon 2 by analogic output automation and erase pressur…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by saad on 2010-10-20 09:54
Dears, I need a help for a failure massege of elektronikon panel which its part no. is (1900 0710 31). the failure massege is :22200000210000009820 3978 10 when i run this panel, this massege appears and remains in display without any change and no step done yet!please, advice me for this problem an…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by DEBASISH GOUDA on 2009-09-15 09:57
ZR-250 Model compressor is easy to use,but it\'s spare details needs to be explained properly.

β€”> Purchase or Repair:
#Atlas Copco by jb aguirre on 2010-10-12 10:16
didnt start

β€”> Purchase or Repair:
#Atlas Copco by Frantz on 2014-12-23 00:44
The Atlas Copco Elektronikon II 1900071011 control/display module in the warehouse is exhibiting unusual behavior not functioning as expected.

β€”> Purchase or Repair:
#Atlas Copco by Daniel Clifton on 2009-09-15 16:45
excellent company

β€”> Purchase or Repair:
#Atlas Copco by Yaselamat Gea on 2009-05-06 03:54
Dear Sir/MadamPlease sent to us Technical manual for Electrikon II.RegardsYaselamat GeaBatam- Indonesia

β€”> Purchase or Repair:
#Atlas Copco by Cassiano on 2008-09-18 02:18
I am needing the manual of compressor GA 55 FF MK4 (Eletronikon II)

β€”> Purchase or Repair:
#Atlas Copco by Albayrak on 2015-07-20 07:20
The Atlas Copco Elektronikon II 1900071012 compressor controller is not working properly.

β€”> Purchase or Repair:
#Atlas Copco by Lucio Roman on 2010-11-06 12:05
GA 160-10A

β€”> Purchase or Repair:
#Atlas Copco by bayo on 2010-02-11 10:27
please i cant start my atlas copco GA 75, it show system failure 10, 00100000.what can i do

β€”> Purchase or Repair:
#Atlas Copco by Abdul Hafeez on 2008-06-26 16:23
if any one problem with screw compressor of any brand.... please do not hesitate to contact us.... regards A H S

β€”> Purchase or Repair:
#Atlas Copco by Ivan Yordanov on 2010-01-24 10:10
Dear Sir ,We need insruction Manual on English language for compressor Atlas Copco type GA-11 FF .Best RegardsIvan YordanovC/E Sanco Starchief.star@sanco.noTel: 0044 1224 372839

β€”> Purchase or Repair:
#Atlas Copco by MEHRDAD YAZDANFAR on 2010-04-12 08:16
hello,i need the maintenance manual of ga 200 -637 air screw compressor .would you please send me?thanks alot

β€”> Purchase or Repair:
#Atlas Copco by Manuel Veliz on 2008-02-17 04:25
i need manual electronikon

β€”> Purchase or Repair:
#Atlas Copco by Elvis rojas on 2021-12-13 01:01
Buenas noches,muy buenos equipos, requiero manual de programaciΓ³n , no permite aran que manual, solicito clave para su arranquΓ© automΓ‘tico

β€”> Purchase or Repair:
#Atlas Copco by alfonso garcia on 2011-02-11 21:39
Good day gents!May we have a copy of the Elektronikon controller manual. Also the manual of the Elektronikon Input Module, we are having issues with the input from the dewpoint sensor.Many thanks....

β€”> Purchase or Repair:
#Atlas Copco by lm on 2008-09-07 11:57
thank you

β€”> Purchase or Repair:
#Atlas Copco by Balasea Adrian on 2012-06-05 08:37
Can you help?GA22-2001 message is system failure 104 what this mean? and how do we rectify the problem. At 1st error code 11 came up but now just the 104 message is shown.Can you help?Regards, Adrian.

β€”> Purchase or Repair:
#Atlas Copco by pt. kereta api indonesia on 2012-01-18 10:39
kami sangat membutuhka wiring diagram sistim controll kompressor atlas copco type GA 708, kami mohon dapat di kirimka ke Email kami ini. Atas kesedian dan budi baiknya kami sampaikan terima kasih.

β€”> Purchase or Repair:
#Atlas Copco by paresh on 2012-01-12 03:38
i have atlas copco GA160 Werror code 110300000000what will we do for remove this error code

β€”> Purchase or Repair:
#Atlas Copco by Basim Ghanim Taha on 2008-07-09 07:19
Dear Atlas copcoGood DayI have two compressors ZR-160 and want to made change over in between theme for every 24 hours automatically.Please send to me technical manuals for how to configure Elctronikon for Star/Stop the compressor automatically and what mean of:- Pressure Band 1- Pressure Band 2- Ho…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by OSCAR VILLEGAS on 2010-11-29 17:51
i have a compressor ga 160 but i dont found its manual. reason why i was looking for one on web.thaksoscar

β€”> Purchase or Repair:
In our plant, we have 2 nos GA 22+ compressors installed & in service for about 4 years. We would like to have Part manual & service manual with exploded drawings for use & reference.

β€”> Purchase or Repair:
#Atlas Copco by barka on 2009-07-05 17:41
sir.Manual For Atlas Copco GA55 Requesedthanks.

β€”> Purchase or Repair:
#Atlas Copco by MAHMOUD ODEH on 2008-07-01 11:12
manual for elektronikon I (new generation )

β€”> Purchase or Repair:
#Atlas Copco by collins kawanga on 2008-11-25 08:38
may you send me the operating/user manual for ELEKTRONIKON FOR GA 250 FF

β€”> Purchase or Repair:
#Atlas Copco by JITENDRA on 2009-11-27 06:44
WE REQUIRE MANUAL FOR G-11 AIR SCREW COMPRESSOR AND ELECTRONIC CONTROL PANEL LATEST VERTION. THIS HAS BEEN FITTED IN OUR NITROGEN PSA SYSTEM.

β€”> Purchase or Repair:
#Atlas Copco by Russell Smith on 2013-10-27 22:34
I am needing all electrical schematic control diagrams

β€”> Purchase or Repair:
#Atlas Copco by Behzad Akbari on 2008-10-05 12:44
Hi,I\'ve lost the Elektronikon Atlas Copco manual.

β€”> Purchase or Repair:
#Atlas Copco by Lovelin on 2013-08-11 23:35
Elektronikon 1900070008 displaying "Fault 5 Motor overload."

β€”> Purchase or Repair:
#Atlas Copco by RAKOTOZANANY on 2012-03-16 04:43
I need a manual for compressor GA7FF because our maintenance for 4000 hours is appear.Or we don\'t have any document for this.

β€”> Purchase or Repair:

Contact Us

πŸš‘Shop LocationπŸ› οΈ

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
πŸš‘ Rush repair shipments only β€” no walk-ins.

πŸ“žPhone

1-336-969-0110

πŸ“¦Mailing AddressπŸš›

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
πŸ“¦ Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.