Atlas Copco Service & Repair Forum

Please could you assit wit a full set of drawings for a Atlas Copco GA 37 ff compressor 525volt Electrical and Mechanical

—> Purchase or Repair: Ticket Image

— Posted by Mike de Beer on 2011-07-29

Reply🗨️Ask a New Question Below❓


Recent Comments Search: "Atlas Copco"

If you need your Atlas Copco unit tested or repaired,
give us a call at 1-336-969-0110.
We offer free estimates and extended warranties on the work performed.
Shipping/Receiving:
Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
Phone: 1-336-969-0110


Recent 1316 Comments

#Atlas Copco by Nguyen Ngoc Quang on 2009-11-06 16:27
My company use air compressor system of atlas copcobut i don\'t have manual about electronikon II, because I can\'t modify any parameter. I want to have manual about atlas copco GA75+ (both mechanical and electrical manual). My company is Cement Hatien 1 stock company. Can you help me?Thanks & best …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by ThanhDat on 2011-04-03 07:38
Dear service Manager!We are using Atlas Copco Compressor GA 15, A MESSAGE IS APPEARING IN LCD THAT \"SYSTEM FAILURE 200\"PLS TELL ME THAT HOW I CAN REMOVE THIS ERROR ,PLS REPLY ME URGENTLY.THANKS

—> Purchase or Repair:
#Atlas Copco by Zahid Iqbal on 2013-07-30 12:32
The Atlas Copco GA45 1900.0590.74 controller is displaying an error message "Motor Overload".

—> Purchase or Repair:
#Atlas Copco by Oscar Mendoza García on 2013-08-15 00:01
cost for repair the controller 1900 0701 04 Atlas copcoCould you please send me Price for repair ?Best regards.Oscar Mendoza G:

—> Purchase or Repair:
#Atlas Copco by Paulo Oliveira on 2016-10-24 10:39
#Atlas Copco by Gajanan Ambekar on 2011-10-25 09:21
Kindly provode us the autorise dealer for our requirment of Regulator 1900 0710 12 for ATLAS COPCO GA 55 COMPRESSORPlease forward us technical details , working for this regulator.Thanks & regards,Gajanan P. AmbekarExecutive – MBD MaterialsMukand LtdThane – Belapur Road,Dighe, Thane India 400605Tel …Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by ahmed on 2010-01-19 07:47
HIGH QUALITY PRODUCTS

—> Purchase or Repair:
#Atlas Copco by nguyentanvu on 2010-07-20 02:15
i have a aircopresor, it is wrong .I dont have diagram to check it so i want your company sent for me diagram book atlascopco serial 02000400121(1900070007)

—> Purchase or Repair:
#Atlas Copco by iulian on 2009-05-26 11:03
Hello! I need your help! I need user manual and messages errors for elektronikon 11! Thank you very much!

—> Purchase or Repair:
#Atlas Copco by Adolfo Omaña Garza on 2008-11-21 16:39
o GA18 air system manual

—> Purchase or Repair:
#Atlas Copco by lotfi on 2012-04-14 17:33
The Atlas Copco 1900-0700-08 controller is not working.

—> Purchase or Repair:
#Atlas Copco by muh.ihsan on 2010-01-21 03:25
we will change GA90VSD to be YD startingwe need wiring diagram Y-Delta connection and wiring diagram elektronikon II

—> Purchase or Repair:
#Atlas Copco by faisal on 2011-12-07 11:07
part no 1900.0590.73.ed.04i find out error e2

—> Purchase or Repair:
#Atlas Copco by Nigel Poole on 2010-01-07 02:29
Im after the user manual for the Electronikon II controller, specifically need to change somesettings on the unit to control the GA75VSD Unit.Manual should have description in it for the direct, indirect setpoints etc.Can any one send me a copy via e-mail please.ThanksNige.

—> Purchase or Repair:
#Atlas Copco by anwar on 2021-10-16 10:39
i have compressor controller ELEKTRONIKON 1900 SERIES ITS display showing code only 110300000000please let me know what is this and please send how to solve problemthanks

—> Purchase or Repair:
#Atlas Copco by SON NGUYEN on 2013-12-18 06:08
We are in need of ATLAS COPCO\'s ELEKTRONIKON MODEL GA75 connection wiring diagram. If you have it, kindly send TO ME

—> Purchase or Repair:
#Atlas Copco by phanhuutong on 2008-12-10 05:17
thank very much

—> Purchase or Repair:
#Atlas Copco by m. imran on 2012-02-15 06:43
Dear SirWe have GA 50 Ndrive and we got problem in compressor which shows an EERROR 7301.Kindly give us detail of this error and how to solve this problem also kindly give us the trouble shooting manuals for feature gauidance .ThanksImran

—> Purchase or Repair:
#Atlas Copco by amar nath chanda on 2011-10-14 15:07
I need controller manual to know the symbol used in controller. like a diagonal arrow in a square box.

—> Purchase or Repair:
#Atlas Copco by Behzad Akbari on 2008-10-05 12:44
Hi,I\'ve lost the Elektronikon Atlas Copco manual.

—> Purchase or Repair:
ples iwork in siemens }we have 6 air compresor nad i have problem in one of them in this air compreso we have damege in a frecuency inverter the old frecuency inverter is somodrive and noe we put a frecuency inverter baldor but the problem is in the comunication betewn elektronicon II andfrecuency i…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by manazir on 2009-12-03 06:09
a soon as posible

—> Purchase or Repair:
#Atlas Copco by Woosik on 2011-03-17 20:49
Hello, I am interested in purchasing an Atlas Copco Elektronikon II 1900 0710 12 controller. Could you please provide me with information on pricing and availability? I am trying to source one quickly. Thank you.

—> Purchase or Repair:
#Atlas Copco by marlon mejala on 2017-08-22 10:27
need to troubleshoot overload error of compressor

—> Purchase or Repair:
#Atlas Copco by AMJADYAC on 2011-04-02 14:26
THANKS FOR ALL

—> Purchase or Repair:
#Atlas Copco by Abdul Hafeez on 2008-06-26 16:23
if any one problem with screw compressor of any brand.... please do not hesitate to contact us.... regards A H S

—> Purchase or Repair:
#Atlas Copco by james mulqueen on 2011-07-13 19:58
machine trips from time to time with same fault convertor motor timeout need to know possible causes please have checked usual things rmba unit and cables crc counters count in units of 1on a only. turn power of and these reset some help please

—> Purchase or Repair:
#Atlas Copco by Syaiful Bachri on 2011-04-20 08:47
I have two Compressor Atlas Copco GA.37, and operation 1998 until now.I think series GA.37 very good. I need Manual Book & Part list because my book lose, so i need you for that.

—> Purchase or Repair:
#Atlas Copco by cheikh on 2012-05-07 10:50
Compresseur Atlas est trés utilisé au sénégal

—> Purchase or Repair:
#Atlas Copco by Alexandr on 2013-12-17 12:17
Good afternoon. Need electrical schematic diagram of the compressor ZT160FF. Thanks in advance.

—> Purchase or Repair:
#Atlas Copco by gabriel on 2011-08-22 17:14
i need electrical diagram for elektronikonll

—> Purchase or Repair:
#Atlas Copco by ali oukhbou on 2009-05-12 17:17
je voulais les schemas electroniques de elektronikon

—> Purchase or Repair:
#Atlas Copco by Abdallah on 2013-01-28 16:07
I have 2 compressor Ga75 and 1 Ga55VsdI have an alarm with Ga55Vsd manfacturing year 2007The alarm is : inverter faliauerI need the soluation The compressor make 35000hr

—> Purchase or Repair:
#Atlas Copco by Gary Wysocki on 2011-06-09 11:05
Atlas Copco Elektronikon II 1900 0710 12 not displaying any data or responding to inputs.

—> Purchase or Repair:
#Atlas Copco by Shott on 2010-04-23 20:36
Atlas Copco Electronikon 1900059812 displaying error code E009.

—> Purchase or Repair:
#Atlas Copco by Dante Linares on 2008-09-21 20:36
Dear Sr.I Need ELECTRONIKON II technical Manual..Dante LinaresC. M. AntaminaTelef 1 51 2173647AncashPeru

—> Purchase or Repair:
#Atlas Copco by m.k on 2008-07-08 08:22
realy i need itgood

—> Purchase or Repair:
#Atlas Copco by ayman badawi on 2012-01-30 08:34
please help me, that we have two compressor type GA-110, when we but them in remote function , the motor of first compressor stopping and elektronikon display give indication ( starter feed back contact ), sorry what did it mean , and i want trouleshooting for elektronikon to know the function of so…Purchase or Repair: Ticket Image...
Show More
#Atlas Copco by Eta Leonard on 2013-12-10 12:55
GA 37 part list manual is of importance to enable my company get genuine parts

—> Purchase or Repair:
#Atlas Copco by hybner on 2013-01-05 08:00
My client's Atlas Copco GA45 1900.0590.74 is having issues with the controller. Can you provide information on how we can troubleshoot or repair this? Thank you.

—> Purchase or Repair:
#Atlas Copco by Pelliculages de l\'ouest on 2010-01-14 08:24
We have a Engine GA 55 VSD with a elektronikon 2 .Can you send the doc from this Elektronikon 2 for read informations .We have no more the documentation.Best regard

—> Purchase or Repair:
#Atlas Copco by naden venkatasami on 2009-12-21 12:11
I have an atlas copco compressor GA75 when switch on power it appears on the display 100300000000 and cannot start the compressor and also no touch switch are working .Please advice urgently

—> Purchase or Repair:
#Atlas Copco by Frank Thomas on 2013-03-03 22:18
Hello, can you please provide us with repair information for the controller of our Atlas Copco GA45 (Part Number 1900.0590.74)? We need a quick replacement but can't find one. Thank you for your help!

—> Purchase or Repair:
#Atlas Copco by Khaerudin on 2010-05-05 11:48
I have two units Screw Compressor Atlas copco GA 22.There is problem in the electrical.I need an wiring electrical for compressor Atlas Copco GA 22,please send me to wiring electrical.Best Regards,Khaerudin

—> Purchase or Repair:
#Atlas Copco by ali boumlik on 2010-10-15 11:40
please send me the catalogue of elektroniken 2best ragard

—> Purchase or Repair:
#Atlas Copco by Oscar Pineda on 2012-06-12 16:13
Hi I just inherited this compressor at our new facility. I have no idea how to make it run, thanks for any helpOsar PinedaLM Westheimer Collision

—> Purchase or Repair:
#Atlas Copco by bill berke on 2012-04-07 01:55
The Atlas Copco 1900-0700-08 controller just failed - drive or board issue. Need immediate attention to resolve the problem.

—> Purchase or Repair:
#Atlas Copco by Constantin Berbec on 2012-04-25 13:02
Dear Service Please to Help me , we have two Electronik II new , when I connect to GA 30 On the LCD Display shown :1220000011000000982039780931How can solve this problem?Thank you

—> Purchase or Repair:
#Atlas Copco by steve on 2011-12-21 22:08
Please send asap, manual on GA7thkx

—> Purchase or Repair:
#Atlas Copco by Ketan J Bhatt on 2012-08-06 13:04
Dear Sir,Pls send elect Drawing for above mention model.RegardsKetan Bhatt

—> Purchase or Repair:

Contact Us

🚑Shop Location🛠️

Industrial Electronic Repair
145 Rockwell Place Ct
Tobaccoville, NC 27050
🚑 Rush repair shipments only — no walk-ins.

📞Phone

1-336-969-0110

📦Mailing Address🚛

Industrial Electronic Repair
931-E S. Main St #204
Kernersville, NC 27284
📦 Mailing Address (for invoices or shipped repairs)
No walk-ins accepted.